Monitoring at the infeed is usually carried out by light barriers, with a light emitter at one side of the frame and a light receiver (photocell) at the other. The device is located between the last transport roller of the creel and the drafting arrangement. If a sliver breaks or runs out, the end falls from the transport roller, passes through the light barrier and stops the machine.