Rieter

A quality monitoring system

Index

(Described by means of the Rieter Quality Monitoring system (RQM))

This continuously controls the sliver mass by means of movable delivery rollers. A precision sensor unit delivers values of the highest accuracy and therefore reliability, thus preventing the production of faulty slivers. The important quality parameters are shown on a monitor, which is part of the system. These are:

  • sliver count;
  • sliver evenness CV%;
  • length variations for 5 cm,10 cm, 25 cm, 50 cm, 1 m, 3 m, 5 m;
  • detection of thick places ≥ 2cm;
  • current spectrogram;
  • advanced diagram displays, e.g. up to a timeframe of more than 10 days.

For example, if the spectrogram shows an error at a certain length, possible reasons for this error in the gearing diagram can be shown on the display.
The RQM can be connected to all Rieter machines and to the  SPIDERweb overall monitoring system for further analysis.

 

Fig. 20 – The Rieter Quality Monitor (RQM) with indication panel