Rieter

Scanning the mass of infeed slivers

Index

Fig. 18 – RSB leveling principle

Fig. 19 – The scanning system

Scanning of mass deviation is performed by the grooved scanning disc and the associated pressure disc (Fig. 18, 1; Fig. 19). The signals are scanned at short, constant intervals, giving very exact values of the mass deviations of the infeed slivers. Determination of mass deviation by the pair of rotating scanning discs of the Rieter RSB scanning system is almost frictionless, thereby enabling the sensor device to employ high working forces, and thus to scan slivers with different bulk very accurately. This is especially advantageous if the individual cans (6 to 8) of infeed sliver are stored for different lengths of time before use. In this case the volume ratio of slivers often differs quite characteristically from can to can.