Optical regulating systems in batch operation

Index

Fig. 72 – Optical regulation

(Example: Marzoli horizontal cleaner)

Four optical monitoring devices (Fig. 72) are mounted in the filling chute, conveyor belt and mixing chamber of the machine.

If the column of material falls below light barrier (2), the preceding machine is switched on and delivers material. When the chute has been filled to such an extent that the material interrupts the light beam in light barrier (1), the machine is switched off again. Light barrier (1) is also an over-fill safety monitor. Light barrier (3) monitors the amount of material in the mixing chamber and controls the drive to conveyor belt (6) and the feed roller of the chute. Light barrier (4) will trigger an alarm if there is no material left on feed conveyor (5).