Rieter

Dust extraction on high-performance cards

Index

More and more countries are enacting rigorous regulations governing permissible dust concentrations in the atmospheres of workrooms. The card releases enormous quantities of dust and it is essential to ensure comprehensive and immediate removal of this waste. For this purpose, modern cards are fully enclosed and subjected to permanent partial vacuum, so that dust and fly can no longer escape from the machine. Within the casing, suction removal systems are provided at some or all of the following positions:

  • in the infeed region;
  • at the entrance to the flats;
  • within the flats;
  • at the exit from the flats;
  • between the main cylinder and the doffer;
  • at the web detaching point;
  • beneath the main cylinder;
  • in the coiler.

The suction removal systems operate continuously to maintain constant conditions on the card. In modern plants the fly- and dust-laden air passes to the air-conditioning equipment. The quantity of suction air per card lies in the range from about 4 000 to 5 000 m3/h.